A company has a database server that requires intensive random write performance on its traditional iSCSI storage running in RAID LUNs.
* Currently, it is running on a physical server.
* The customer would like to consolidate its existing environment by virtualizing.
When architects a vSphere 6.5 design, which three components would ensure storage performance and availability? (Choose three.)
Power has just been restored to the data center after a catastrophic power failure. All storage and networks are back online.
In what order should the following systems be powered on?
Customer Information
The Customer labtown is looking to purchase a new storage system and has hired you to create a logical design. Labtown requires no single points of failure when it comes to the fabric connecting the storage. Labtown has already decided that the new storage system will be using fibre to re-use as much of the previous hardware as possible to increase ROI. Labotwn would also like a tiered disk system broken into three categories with the database sitting in the fastest tier, the two web servers sitting in the medium tier, and the file server sitting in the slowest tier.
Create a logical design for Labtowns new Storage System
Requirements
- Create a tiered storage system for Labtown - No single points of failure - Insure storage performance SLA's are met with the four line of business VM's Instructions
- Place VM's on the bottom of the page and connect them with the connector to the storage LUN they will belong to.
- Connect the storage LUN with the service processor with the connector
- Connect the storage processors to the SAN switch
- Place HBA's just below the host, as long as they are close to the host points will be scored
- Connect HBA's to SAN switches with either the Fixed, MRU, or RR Connector to dictate the PSP Policy for storage on the ESXi host.
A customer is virtualizing a mission-critical Microsoft SQL database and needs a configuration that provides optimal NUMA performance.
* There are two possible clusters that the database virtual machine could reside in: Cluster A is vSphere 6.0 and Cluster B is vSphere 6.5.
* All ESXi hosts contain dual Intel Xeon E5-2650 v3 processors (ie: 2 socket, 10 cores per socket) and 256Gb RAM with vNUMA in its default configuration.
Given this scenario, which three statements are true? (Choose three.)
You have been tasked with creating a vSphere 6.5 data center design for an organization. During the key stakeholder and SME interviews. a set of goals, requirements, assumptions and constraints were identified. Evaluate each of the requirements, assumptions, and constraints (RAC) and determine which design characteristics apply.
Match each of the Requirements, Assumptions and Constraints by dragging the RAC buttons (R1-R5) over the text of the appropriate Design Characteristic.
NOTE: RACs may fit one or more of the Design Characteristics.